Industrial Hygiene Surface Sampling Method Summary

Name(s) of Compound Tobramycin
CAS # 32986-56-4
Method Report Number SBM180-R0
Analytical Method EIA
Swabbing Media Four CleanTips swabs TX740B; in glass test tube with screw cap
Swabbing Solution DI water
Quantification Limit 10 ng/sample
Average Recovery from Stainless Steel - 90.1%
Epoxy Resin Bench – 77.0%
Storage Conditions At least 21 days at ambient temperature, 2 - 8 °C or ~ -20 °C
Shipping Requirements Ambient temperature, overnight
Date Issued 07/20/2010

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.