Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Etretinate, Tegison, Tigason
CAS # 54350-48-0
Method Report Number SBM002-R0
Analytical Method HPLC-UV
Sampling Media 37 mm Teflon filter, 0.5 micron pore size, support pad, 2-pc polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 125 L
Quantification Limit 0.05μg/cassette
Storage Conditions At least 21 days at ~ -4 °C
Shipping Requirements On ice pack, covered from light
Date Issued 05/07/1998

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.