Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Thalidomide
CAS # 50-35-1
Method Report Number SBM022–R0
Analytical Method HPLC-UV
Sampling Media Two 37 mm quartz filters, 1 micron pore size (Whatman), in 2-piece polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 120 L
Quantification Limit 30 ng/sample
Storage Conditions At ambient temperature for at least 7 days
At 2 - 8 °C for at least 14 days
Shipping Requirements Ambient temperature
Date Issued 05/01/2000

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.

<< go back