Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Retinol; all-trans-Retinol; Axerophthol; Vitamin A alcohol; Vitamin A
CAS # 68-26-8
Method Report Number SBM108-R0
Analytical Method HPLC-UV
Sampling Media 25 mm Teflon, 1 micron pore size; treated with 5% BHT in IOM cassette
Sampling Rate 2 L/min
Recommended Minimum Sampling Volume 91 L
Recommended Maximum Sampling Volume 240 L
Quantification Limit 0.1μg/sample
Storage Conditions 1 week at ~ -20 °C
Shipping Requirements Overnight on dry ice
Date Issued 02/23/2006

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.

<< go back