Industrial Hygiene Surface Sampling Method Summary



Name(s) of Compound Ranolazine (Free Base)
CAS # 95635-55-5
Method Report Number SBM183–R0
Analytical Method HPLC-UV
Swabbing Media 37 mm glass fiber filters, 1 micron pore size (A/E)
Swabbing Solution DI water
Quantification Limit 0.5μg/sample
Average Recovery from Bench – 65%
Floor – 32%
Storage Conditions At ambient temperature for least 21 days
At ~ -20 °C for at least 21 days
Shipping Requirements Ambient temperature
Date Issued 09/07/2010

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.