Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Norethindrone
CAS # 68-22-4
Method Report Number SBM-EHS011
Analytical Method HPLC-UV
Sampling Media 37 mm Glass Fiber Filter 1 µm pore size, support pad assembled into 37 mm two-piece polypropylene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 100 L
Quantification Limit 0.01μg/sample
Storage Conditions Ambient temperature for at least 1 week
Shipping Requirements Ambient temperature, overnight
Date Issued 06/10/1991

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.