Industrial Hygiene Surface Sampling Method Summary

Name(s) of Compound Niraparib Tosylate
CAS # 1038915-64-8
Method Report Number SBM260-R0
Analytical Method HPLC-FL/UV
Swabbing Media CleanTips swabs, 2 swabs, cat # TX715, TWTexwipe
Swabbing Solution Methanol/Water: 9/1
Quantification Limit 10 ng/sample
Average Recovery from Stainless Steel - 76.1%
Floor Tile - 65.1%
Glass – 83.7%
Painted Metal – 71.6%
Bench – 60.6%
Detection Limit of Analytical Method 1 ng/mL
Storage Conditions At ambient temperature
At 2 - 8 °C or at ~ -20 °C for at least 3 weeks
Shipping Requirements Ambient temperature
Date Issued 02/13/2015

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at

<< go back