Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Nafarelin, Nafarelin Acetate
CAS # 86220-42-0
Method Report Number SBM081-R4
Related Document(s) SBM063; SBM063-Addendum 1; SBM081-R3 surface
Analytical Method EIA
Sampling Media 37 mm Teflon, 1 micron pore size; support pad; in 2-pc polypropylene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 100 L
Quantification Limit 0.1 ng/sample
Storage Conditions At least 7 days at 2-8 °C
At least 17 days at ~ -20 °C
Shipping Requirements On ice pack, overnight
Date Issued 08/20/2015

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at