Industrial Hygiene Surface Sampling Method Summary

Name(s) of Compound Mannitol, D-Mannitol
CAS # 69-65-8
Method Report Number SBM190-R0
Analytical Method HPLC-EC
Swabbing Media Two CleanTips Swabs, TX714A; in polypropylene centrifuge tube with screw cap
Swabbing Solution DI Water
Quantification Limit 10 ng/sample
Average Recovery from N/A
Storage Conditions At least 14 days at 2 - 8 °C
Shipping Requirements On ice pack, overnight
Date Issued 05/03/2011

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at

<< go back