Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Isotretinoin
CAS # 4759-48-2
Method Report Number SBM-EHS053–R0 Add.1 Air
Analytical Method HPLC-UV
Sampling Media 37 mm teflon filter, 1 micron pore size, support pad, in 2-piece polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 45 L
Quantification Limit 100 ng/sample
Storage Conditions At ~ -20 °C for at least 21 days, protected from light
Shipping Requirements Cold on ice pack, protected from light
Date Issued 07/13/2009

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.

<< go back