Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Insulin
CAS # 11061-68-0
Method Report Number SBM013–R0
Analytical Method HPLC-UV
Sampling Media 37 mm Teflon Filter, 1 micron pore size; support pad; in 3-pc polypropylene cassette
Sampling Rate 2 L/min
Recommended Minimum Sampling Volume 120L
Quantification Limit 2μg/filter
Storage Conditions At least 2 weeks at ~4 °C
Shipping Requirements Cold, dry ice
Date Issued 04/26/1999

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at