Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound (S, R) Hydroxycarbamate Ro 61-4683
Method Report Number SBM008
Analytical Method HPLC-UV
Sampling Media 37 mm Glass Filter, 1 micron pore size; support pad; in 2-pc polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 200 L
Quantification Limit 20μg/cassette
Storage Conditions At least 2 weeks at 2 - 8 °C
Shipping Requirements Ambient temperature
Date Issued 02/03/1999

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at