Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Ganciclovir, DHPG
CAS # 82410-32-0
Method Report Number SBM033-R0 and EHS 005
Analytical Method HPLC-UV
Sampling Media 37 mm Glass Filter, 1 micron pore size; support pad; in 2-pc polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 40 L
Recommended Maximum Sampling Volume Do not exceed 200L
Quantification Limit 100 ng/sample
Storage Conditions At least 3 weeks at ambient temperature
At least 3 weeks at 2 - 8 °C
Shipping Requirements Ambient temperature
Date Issued 08/30/2001

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.