Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound 5-Fluorouracil, Efludex, 5-FU
CAS # 51-21-8
Method Report Number SBM-EHS063–R0; SBM-EHS063–R0 Add. 2 Air
Analytical Method HPLC-UV
Sampling Media 37 mm teflon filter, 1 micron pore size, support pad, in 2-piece polystyrene cassette
25 mm teflon filter, 1 micron pore size, in IOM sampler
Sampling Rate 3 L/min
2 L/min
Recommended Minimum Sampling Volume 50 L
Quantification Limit 25 ng/sample
Storage Conditions At ~ -4 °C for at least 21 days
Protected from light
Shipping Requirements Ambient temperature
Date Issued 01/07/2010

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at