Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Everlase, Protease from Bacillus licheniformis
CAS # 9014-01-1
Method Report Number SBM195-R0
Analytical Method ELISA
Sampling Media 25 mm Teflon Filter, 1 micron pore size, (Millipore Cat. # FALP02500) placed in cassette filter assembly (SKC, cat No 225-71A), and IOM sampler (SKC, Cat No 225-70A)
Sampling Rate 2 L/min
Recommended Minimum Sampling Volume 30 L
Quantification Limit 0.18 ng/sample
Storage Conditions At least 7 days at ambient temperature
At least 28 days at 2 - 8 °C, or ~ -20 °C
Shipping Requirements On ice pack
Date Issued 03/23/2012

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.