Industrial Hygiene Surface Sampling Method Summary

Name(s) of Compound Enclomiphene Citrate, Trans-Clomiphene Citrate, Androxal
CAS # 7599-79-3
Method Report Number SBM231–R0
Analytical Method HPLC-UV
Swabbing Media Two 37mm Glass fiber filters, type A/E
Swabbing Solution Methanol
Quantification Limit 100 ng/sample
Average Recovery from HDPE Plastic - 99.8%
Stainless Steel - 94.5%
Stone Floor - 94.8%
Storage Conditions At ambient temperature for at least 7 days
At ~ –20 °C for at least 2 weeks
Protected from light
Shipping Requirements Ambient temperature, protected from light
Date Issued 12/20/2013

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.