Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Efavirenz
CAS # 154598-52-4
Method Report Number SBM171-R0
Analytical Method HPLC-UV
Sampling Media 37 mm Teflon filter, 0.45 micron pore size, support pad, 2-pc polystyrene cassette
Sampling Rate 2 L/min
Recommended Minimum Sampling Volume 30 L
Quantification Limit 25ng/cassette
Storage Conditions At least 7 days at ambient temperature
At least 60 days at ~ -20 °C
Shipping Requirements Ambient temperature
Date Issued 03/02/2010

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.

<< go back