Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Doxifluridine
CAS # 3094-09-5
Method Report Number SBM-EHS061–R0
Analytical Method HPLC-UV
Sampling Media 37 mm teflon filter, 1 micron pore size, support pad, in 2-piece polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 50 L
Quantification Limit 25 ng/sample
Storage Conditions At ~ -4 °C for at least 21 days, protected from light
Shipping Requirements Ambient temperature
Date Issued 12/17/1997

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.