Industrial Hygiene Surface Sampling Method Summary



Name(s) of Compound DMx and conjugated DMx (cDMx)
CAS # N/A
Method Report Number SBM262-R1
Analytical Method ELISA
Swabbing Media Two CleanTips swabs TX714A; in polypropylene test tube with dual position cap containing 1 mL of stabilizing buffer
Swabbing Solution 10% Ethanol in 0.05 M carbonate/bicarbonate buffer pH 9.6
Quantification Limit 20 / 100 ng/sample
Storage Conditions At least 7 days at 2 - 8 °C
Shipping Requirements On ice pack, overnight
Date Issued 07/09/2015

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.