Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Dimethyl Fumarate, DMF, BG12
CAS # 624-49-7
Method Report Number SBM193–R0
Analytical Method HPLC-UV
Sampling Media Sorbent tube, Silica gel OVS (Glass Fiber Filter), 13>8x75 mm, 2 section, 260/520 mg sorbent, with GO ends, FFGT separators, V tube cover, SKC product cat. 226-99
Sampling Rate 2 L/min
Recommended Minimum Sampling Volume 50 L
Quantification Limit 1.8μg/sample
Storage Conditions Stable at least 21 days at 2 - 8 °C
Shipping Requirements On ice
Date Issued 08/05/2011

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at