Industrial Hygiene Surface Sampling Method Summary



Name(s) of Compound Actinomycin D; Dactinomycin
CAS # 50-76-0
Method Report Number SBM032-R0
Analytical Method HPLC-UV
Swabbing Media Two 37 mm glass fiber filters, 1 micron pore size (A/E)
Swabbing Solution Methanol
Quantification Limit 100 ng/sample
Average Recovery from Stainless Steel - 94%
Storage Conditions At least 3 days at ambient temperature
At least 14 days at ~ –20 °C
Shipping Requirements Ambient temperature
Date Issued 09/29/2001

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.