Industrial Hygiene Air Sampling Method Summary



Name(s) of Compound Calcitriol; 1α, 25-dihydroxyvitamin D3; 1α, 25-dihydroxycholecalciferol; Rocaltrol
CAS # 32222-06-3
Method Report Number EHS051-Addendum 2-R0 air
Analytical Method RIA
Sampling Media 37 mm Teflon, 0.45 micron pore size; support pad; in 2-pc polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 50 L
Recommended Maximum Sampling Volume Do not exceed 150 L
Quantification Limit 0.1 ng/sample
Storage Conditions At least 14 days at 2 - 8 °C
Shipping Requirements On ice pack, overnight, protected from light
Date Issued 06/30/2006

If you wish to submit a sample, please follow the sample submission procedures found at safebridge.com/laboratory/sample-submission. SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at safebridge.com.