Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound T4, Levothyroxine, Porcine Thyroxin in Armour Thyroid Powder
Method Report Number SBM234-R0
Analytical Method ELISA
Sampling Media 25 mm Teflon filter, 1 micron pore size; support pad; in 2-piece polypropylene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 210 L
Quantification Limit 2.59 ng/sample
Storage Conditions At least 21 days at ambient temperature, 2 - 8 °C, and ~ -20 °C
Shipping Requirements Ambient temperature, overnight
Date Issued 01/15/2014

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.

SafeBridge Consultants, Inc. is the premier occupational health and safety and risk assessment consulting firm to the pharmaceutical, biotechnology, and fine chemical industry. Learn more at