Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Amikacin Sulfate
CAS # 37517-28-5
Method Report Number SBM149–R0
Analytical Method HPLC-UV
Sampling Media 25 mm teflon filter, 0.45 micron pore size, support pad, in 3-piece opaque polypropylene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 100 L
Quantification Limit 4μg/sample
Storage Conditions At ambient temperature for at least 9 days
At 2 - 8 °C or ~ -20 °C for at least 24 days
Shipping Requirements Ambient temperature, protected from light
Date Issued 06/24/2008

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.