Industrial Hygiene Air Sampling Method Summary

Name(s) of Compound Acitretin
CAS # 55079-83-9
Method Report Number SBM-EHS035–R0
Analytical Method HPLC-UV
Sampling Media 37 mm Teflon filter, 1 micron pore size, support pad, in 2-piece polystyrene cassette
Sampling Rate 3 L/min
Recommended Minimum Sampling Volume 100 L
Quantification Limit 50 ng/sample
Storage Conditions At ambient temperature for at least 42 days, protected from light
At 2 - 8 °C for at least 42 days
Shipping Requirements Ambient temperature, protected from light
Date Issued 12/01/1995

If you wish to submit a sample, please follow the sample submission procedures found at SafeBridge regularly develops new and custom industrial hygiene air and surface sampling methods. For more information, please call (650) 961-4820.